| BRAKE POWER REQUIRED | 20.0 HORSEPOWER |
| COMPRESSOR COOLING MEDIUM | AIR |
| COMPRESSOR QUANTITY | 1 |
| COMPRESSOR SPEED AT RATED CAPACITY IN RPM | 900.0 |
| COOLING SYSTEM DESIGN | SINGLE |
| CYLINDER ARRANGEMENT STYLE | RADIAL DESIGN |
| CYLINDER QUANTITY | 4 |
| DISCHARGE FLOW RATE | 22.000 CUBIC FEET PER MINUTE |
| FUNCTIONAL DESCRIPTION | REFILL SELF CONTAINED BREATHING APPARATUS (SCBA) CYLINDERS WITH PURIFIED AIR |
| GAS COOLING EQUIPMENT TYPE | AIR TYPE AFTERCOOLER AND AIR TYPE INTERCOOLER |
| GAS FOR WHICH DESIGNED | AIR |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | K180 BARE COMPRESSOR |
| PRIME MOVER COOLING MEDIUM | AIR |
| RECIPROCATING COMPRESSOR DESIGN | SINGLE ACTING |
| SPECIAL FEATURES | PURIFICATION SYSTEM UTILIZES REPLACEABLE CARTRIDGES |
| SPECIAL TEST FEATURES | THE BREATHING AIR STATION SHALL BE TESTED BY THE MANUFACTURER PRIOR TO SHIPMENT, A COPY OF THE MANUFACTURERS TEST REPORT SHALL ACCOMPANY THE STATION AT SHIPMENT |
| SPECIFICATION/STANDARD DATA | 57328-UNII/26 K180 MANUFACTURERS SPECIFICATION |
| STAGE QUANTITY | 4 |
| SUPPLEMENTARY FEATURES | THE PURIFICATION SYSTEM SHALL PURIFY HIGH PRESSURE AIR TO A QUALITY THAT MEETS OR EXCEEDS THE REQUIREMENTS OF CGA PAMPHLET G-7, COMPRESSED AIR FOR HUMAN RESPIRATION, ANSI/CGA G-7.1, COMMODITY SPECIFICATION FOR AIR, GRADE E AND ALL OTHER RECOGNIZED STANDARDS FOR BREATHING AIR |
| UNLOADER TYPE | AUTOMATIC |