| CONNECTION TYPE | RAISED FACE FLANGE 1ST END |
| CONNECTION TYPE | RAISED FACE FLANGE 2ND END |
| INSIDE SURFACE CONDITION | SMOOTH |
| RAISED FACE DIAMETER | 2.135 INCHES NOMINAL 2ND END |
| RAISED FACE DIAMETER | 2.760 INCHES NOMINAL 1ST END |
| BOLT HOLE QUANTITY | 4 1ST END |
| BOLT HOLE QUANTITY | 4 2ND END |
| CONNECTION STYLE | RAISED SWIVEL 1ST END |
| CONNECTION STYLE | RAISED SWIVEL 2ND END |
| FLANGE LENGTH | 2.375 INCHES NOMINAL 2ND END |
| FLANGE LENGTH | 3.000 INCHES NOMINAL 1ST END |
| TEMP RATING | -40.0 DEG FAHRENHEIT AND 160.0 DEG FAHRENHEIT SINGLE RESPONSE |
| BURST TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| HYDROSTATIC TEST PRESSURE | 1000.0 POUNDS PER SQUARE INCH |
| MAXIMUM OPERATING PRESSURE | 500.0 POUNDS PER SQUARE INCH |
| BOLT HOLE DIAMETER | 0.266 INCHES NOMINAL 2ND END |
| BOLT HOLE DIAMETER | 0.328 INCHES NOMINAL 1ST END |
| END CONNECTION DESIGN | ELBOW 1ST END |
| END CONNECTION DESIGN | ELBOW 2ND END |
| FLOW ANGLE | 12.0 DEGREES 2ND END |
| FLOW ANGLE | 45.0 DEGREES 1ST END |
| MINIMUM INSIDE BENDING RADIUS | 11.000 INCHES |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| END FLANGE CONSTRUCTION | SOLID 1ST END |
| END FLANGE CONSTRUCTION | SOLID 2ND END |
| FEATURES PROVIDED | REUSABLE END FITTINGS |
| SPECIAL FEATURES | FIRST END HAS A 1.500 IN. OD TUBE GRADUATED TO 2.000 IN. OD AT FLANGE END WITH TWO BENDS WITH A BOSS FITTING P/N AND 10050 LOCATED 5.500 IN. FROM FLANGE |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED COTTON CORD AND 2ND LAYER BRAIDED STEEL WIRE AND OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD |
| INSIDE DIAMETER | 1.375 INCHES NOMINAL |
| VACUUM IN TORR | 50.8 |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 1.812 INCHES NOMINAL 2ND END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 2.375 INCHES NOMINAL 1ST END |
| OUTSIDE DIAMETER | 1.695 INCHES NOMINAL |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) 1ST END |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) 2ND END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 1.812 INCHES NOMINAL 2ND END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 2.375 INCHES NOMINAL 1ST END |
| OUTER COVERING ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND OIL RESISTANT |
| FLANGE WIDTH | 2.375 INCHES NOMINAL 2ND END |
| FLANGE WIDTH | 3.000 INCHES NOMINAL 1ST END |
| FLANGE THICKNESS | 0.359 INCHES NOMINAL 1ST END |
| FLANGE THICKNESS | 0.359 INCHES NOMINAL 2ND END |
| RAISED FACE HEIGHT | 0.020 INCHES NOMINAL 1ST END |
| RAISED FACE HEIGHT | 0.020 INCHES NOMINAL 2ND END |
| MEASURING METHOD AND LENGTH | 15.000 INCHES NOMINAL WORKING |