5945-00-094-8178 PLUNGER,SOLENOID Index 1650-00-094-8184 VALVE,LINEAR,DIRECTIONAL CONTROL

National Stock Number:
4810-00-094-8180

Federal Supply Class:
4810

National Item Identification Number:
000948180

Description:
VALVE,LINEAR,DIRECTIONAL CONTROL

Detail:
A manually or power operated valve having three or more ports. The direction of the flow through the various ports is controlled by either one or more reciprocating slide(s) or spool(s) with recess areas which mate with ports in an integral or replaceable ported sleeve, or one or more poppet(s). It is designed to change the direction of fluid flow from one valve port to another. An off (no flow) position is not a flow pattern. The valve is designed to actuate various components of a fluid system. A power operated valve may have a manual override. For items which stop, start, or change the flow of fluid, see: VALVE, SOLENOID. Excludes VALVE, PLUG. See also SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; and VALVE ASSEMBLY.


Manufacturer Information:
10-247381205THE BOEING COMPANY
2503681982HYDRO-AIRE AEROSPACE CORP
852805818876U S ARMY AVIATION AND MISSILE COMMAND
S1565-6183178286SIKORSKY AIRCRAFT CORPORATION


Techincal Specification:
END CONNECTION QUANTITY3
BODY MATERIALALUMINUM ALLOY
CONNECTION TYPETHREADED INTERNAL BOSS
CRITICALITY CODE JUSTIFICATIONFEAT AND AGAV
CURRENT RATING IN AMPS1.2
FLOW PATTERN QUANTITY3
MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED3000.0 POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE
MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED160.0 FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE
NOMINAL THREAD SIZE0.375 INCHES
SPECIAL FEATURESMANUFACTURERS SUGGESTED NAME IS VALVE ASSY, SOLENOID, 3 WAY, 2 POSITION; OPERATING TEMP ABMIENT -65 TO +160 DEG FEG; WEIGHT 1.5 LBS; VOLTAGE RANGE 18 TO 28 VDC, 3 PORTS PER AND10050-6; 5.53 IN. LG., 1.81 IN. WIDE, 2.50 IN. HT.; ELEC CONNECTOR AN3102A-10SL-4P
SPOOL POSITION QUANTITY2
SPOOL QUANTITY1
THREAD CLASS3B
THREAD SERIES DESIGNATORUNF
VALVE DISCHARGE FLOW RATE3.2 GALLONS PER MINUTE
VALVE OPERATION METHODSOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE28.0 DC