ELECTRICAL RESISTANCE | 1.280 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 1.000 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 32.870 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 2.170 KILOHMS 3RD INTERMEDIATE RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 71.250 KILOHMS HIGHEST RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 900.000 OHMS LOWEST RESISTANCE VALUE |
ELECTRICAL RESISTANCE | 5.520 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 0.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 65.0 |
BODY HEIGHT | 0.340 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
BODY LENGTH | 2.470 INCHES MAXIMUM |
BODY WIDTH | 3.480 INCHES MINIMUM AND 3.500 INCHES MAXIMUM |
IDENTICAL VALUE RESISTOR QUANTITY | 2 2ND INTERMEDIATE RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 2 3RD INTERMEDIATE RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 2 5TH INTERMEDIATE RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 2 HIGHEST RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 4 LOWEST RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 4 1ST INTERMEDIATE RESISTANCE VALUE |
IDENTICAL VALUE RESISTOR QUANTITY | 4 4TH INTERMEDIATE RESISTANCE VALUE |
INCLOSURE METHOD | ENCAPSULATED |
POWER DISSIPATION RATING IN WATTS | 5.800 TOTAL NETWORK |
RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 EACH RESISTOR |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | FLAT PACK |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -40.0 TO 105.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 FIRST TEMP COEFFICIENT |
TERMINAL LENGTH | 1.500 INCHES MINIMUM |
TERMINAL QUANTITY | 26 |
TERMINAL TYPE | WIRE LEAD |