AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY LENGTH | 0.500 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.053 INCHES NOMINAL |
INCLOSURE TYPE | ENCAPSULATED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | THERMAL RESISTOR P/N A123-89 IS SUPPLIED WITH A HOLDER P/N A123-94 |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -3.0 TO 3.0 |
ZERO POWER RESISTANCE | 100.000 KILOHMS |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.4 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 36.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 556.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.8 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
STYLE DESIGNATOR | ROD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.016 INCHES NOMINAL |
TERMINAL LENGTH | 1.375 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
THERMAL TIME CONSTANT IN SECONDS | 20.0 |