5905-00-105-7446 RESISTOR,FIXED,WIRE WOUND Index 5905-00-105-7450 RESISTOR,FIXED,WIRE WOUND,INDUCTIVE

National Stock Number:
5905-00-105-7448

Federal Supply Class:
5905

National Item Identification Number:
001057448

Description:
RESISTOR,FIXED,WIRE WOUND

Detail:
INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.


Manufacturer Information:
1192-1502F58880MEGGITT (NEW HAMPSHIRE), INC
207A1502F05347ULTRONIX INC
210A1502F05347ULTRONIX INC
210A15K00F44655OHMITE HOLDING, L.L.C.
906D725-183843SUNDSTRAND CORP ELECTRIC POWER SYSTEMS DIV
906D725-199167HAMILTON SUNDSTRAND CORPORATION


Techincal Specification:
ELECTRICAL RESISTANCE15.000 KILOHMS
AMBIENT TEMP AT FULL RATED POWER100.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER145.0
BODY DIAMETER0.250 INCHES NOMINAL
BODY LENGTH1.000 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
PART NAME ASSIGNED BY CONTROLLING AGENCYRESISTOR, FIXED, WIRE WOUND, NONINDUCTION
POWER DISSIPATION RATING IN WATTS0.750 FREE AIR
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 125.0
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT83843-906D725 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).