BODY OUTSIDE DIAMETER | 0.100 INCHES NOMINAL |
BODY WIDTH | 0.029 INCHES NOMINAL |
INCLOSURE TYPE | ENCAPSULATED |
OVERALL WIDTH | 0.130 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 300.0 CELSIUS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.5 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 4TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 5TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 360.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 51.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 54.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
ZERO POWER RESISTANCE | 3.000 KILOHMS |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.40 |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 24.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
STYLE DESIGNATOR | DISK |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 200.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 300.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.013 INCHES NOMINAL |
TERMINAL LENGTH | 1.000 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
THERMAL TIME CONSTANT IN SECONDS | 8.0 |