5910-00-113-3611 CAPACITOR,VARIABLE,AIR DIELECTRI Index 5950-00-113-3614 TRANSFORMER,POWER

National Stock Number:
5905-00-113-3613

Federal Supply Class:
5905

National Item Identification Number:
001133613

Description:
RESISTOR,VARIABLE,NONWIRE WOUND,

Detail:
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.


Manufacturer Information:
2100-22161LQK8KEYSIGHT TECHNOLOGIES, INC.
2100-221628480HEWLETT-PACKARD COMPANY
2100-22167ZXR5KEYSIGHT TECHNOLOGIES INC
411/4/20560/502K0668LEONARDO UK LTD
4174378P994117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
5016076-003K1182THALES UK LIMITED DBA THALES UK LTDTRAINING AND SIMULATION
62-208-173138BI TECHNOLOGIES CORPORATION
82PR5K73138BI TECHNOLOGIES CORPORATION


Techincal Specification:
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION240.0 NOMINAL
ELECTRICAL RESISTANCE PER SECTION5.0 KILOHMS SINGLE SECTION
ACTUATOR TRAVEL CONTROL FEATURESTOPS
ACTUATOR TYPEFLUSH DRIVE WITH SLOT-HOLE
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER85.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER150.0 SINGLE SECTION
BODY DIAMETER0.281 INCHES NOMINAL
BODY LENGTH0.250 INCHES NOMINAL
BODY STYLECYLINDRICAL
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.100 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.200 INCHES NOMINAL
MOUNTING METHODTERMINAL
POWER DISSIPATION RATING PER SECTION IN WATTS0.5 FREE AIR SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE PER SECTION IN PERCENT-10.0 TO 10.0 SINGLE SECTION
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG240.0 NOMINAL
SECTION QUANTITY1
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-100.0 TO 100.0 SINGLE SECTION
TERMINAL LENGTH0.187 INCHES NOMINAL
TERMINAL LOCATIONREAR END
TERMINAL TYPE AND QUANTITY3 PIN