5950-00-132-2281 COIL,RADIO FREQUENCY Index 5905-00-132-2283 RESISTOR,THERMAL

National Stock Number:
5905-00-132-2282

Federal Supply Class:
5905

National Item Identification Number:
001322282

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
0550F10372819OHMITE HOLDING, L.L.C.
0550F5-10372819OHMITE HOLDING, L.L.C.
62A114C35-210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY LENGTH0.630 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.220 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS11.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP15.3 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 OHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-1.56
ZERO POWER RESISTANCE AT SPECIFIED TEMP27.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.8 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP5.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.8 OHMS 3RD RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORROD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-25.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.031 INCHES NOMINAL
TERMINAL LENGTH1.375 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS25.0


Click here to Register for Free 30-day Trial