5910-00-051-6212 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-00-051-6215 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-00-051-6214

Federal Supply Class:
5910

National Item Identification Number:
000516214

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
0838050W5R0 229K18796MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
352250018298H0203THALES NEDERLAND B.V.
CK60BX2R2K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-11015/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
VBE726CBX2E2KH0203THALES NEDERLAND B.V.


Techincal Specification:
BODY DIAMETER0.280 INCHES NOMINAL
BODY LENGTH0.120 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, RADIAL TERMINALS
CAPACITANCE VALUE PER SECTION2.200 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.250 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.5000
INSULATION RESISTANCE AT REFERENCE TEMP200000.0 MEGOHMS
MATERIALCERAMIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION1000.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-11015/9 GOVERNMENT SPECIFICATION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-11015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION