5315-00-059-0661 PIN,COTTER Index 5315-00-059-0678 PIN,COTTER

National Stock Number:
5910-00-059-0674

Federal Supply Class:
5910

National Item Identification Number:
000590674

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
663FR22354W84411AMERICAN SHIZUKI CORP
NO PRIMARY REF 00-059-0674IREF0THIS NCAGE IS USED TO INFORM THAT THE DESIGN CONTROL AUTHORITY CANNOT BEESTABLISHED OR THE ITEM OF SUPPLY IS NO LONGER M


Techincal Specification:
BODY HEIGHT0.297 INCHES MAXIMUM
BODY LENGTH0.750 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.453 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION22000.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.782 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
DIELECTRIC MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.5000
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP500.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHM-MICROFARADS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION400.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION