5905-00-062-6663 RESISTOR,FIXED,FILM Index 5910-00-062-6667 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-062-6664

Federal Supply Class:
5910

National Item Identification Number:
000626664

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
102P2556289SPRAGUE ELECTRIC CO WORLD HQS
103P2596289KUT KWICK CORP
103P525A56289SPRAGUE ELECTRIC CO WORLD HQS
7901692-1690536LOCKHEED MARTIN CORP
CZ24BEF10411693CHARLOTTE SUPPLY CO
CZ24BKF10481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M1169317-CZ24BKF10456289SPRAGUE ELECTRIC CO WORLD HQS
M1169317-CZ24BKF10481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-11693/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-11693/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.562 INCHES NOMINAL
BODY LENGTH1.375 INCHES NOMINAL
BODY STYLEW/THD BUSHING MTG, TERMINALS ON OPPOSITE ENDS
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
CONTINUOUS CURRENT RATING IN AMPS10.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP18000.0 MEGOHMS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
NOMINAL THREAD SIZE0.312 INCHES
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION600.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORFEEDTHROUGH
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD W/TERMINAL LUG
TEST DATA DOCUMENT81349-MIL-C-11693/7 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial