5910-00-075-9609 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5940-00-075-9617 POST,BINDING,ELECTRICAL

National Stock Number:
5910-00-075-9612

Federal Supply Class:
5910

National Item Identification Number:
000759612

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
4860-785324655GENRAD INC
4860-785362015IET LABS INC
663UW20311W284411AMERICAN SHIZUKI CORP
GR9 0.02-1-10084411AMERICAN SHIZUKI CORP
GR9.02 1PCT 100VDC84411AMERICAN SHIZUKI CORP
W22104-1203W32159WEST CAP ARIZONA


Techincal Specification:
DIELECTRIC MATERIALPLASTIC POLYETHYLENE TEREPHTHALATE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
BODY DIAMETER0.156 INCHES NOMINAL
BODY LENGTH0.500 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION20000.000 PICOFARADS SINGLE SECTION
CASE MATERIALPLASTIC
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP500.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP70000.0 MEGOHM-MICROFARADS
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
PROPRIETARY CHARACTERISTICSPACS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL LENGTH1.625 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-1.00/+1.00 PERCENT SINGLE SECTION