5950-00-102-6913 TRANSFORMER,POWER Index 3020-00-102-6920 GEAR,SPUR

National Stock Number:
5910-00-102-6915

Federal Supply Class:
5910

National Item Identification Number:
001026915

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
2548721-1610001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
39D238G050JT40P569B. MICROFARADS, INC.
39D238G050JT462643UNITED CHEMI-CON, INC.
39D238G050JT60P569B. MICROFARADS, INC.
39D238G075JT456289SPRAGUE ELECTRIC CO WORLD HQS
CS13BE106K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
D10029-14531849GREGORY ENGINEERING CORP
T60501411636090LOCKHEED MARTIN LIBRASCOPE CORP


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEPLAIN FOIL
BODY DIAMETER1.000 INCHES NOMINAL
BODY LENGTH3.625 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION2300.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP5.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP1.000 MILLIAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT45.0000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-20.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL LENGTH2.500 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT10001-2548721-16 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-10.00 TO 75.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial