BODY DIAMETER | 0.478 INCHES MAXIMUM |
BODY LENGTH | 1.251 INCHES MAXIMUM |
BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
CAPACITANCE VALUE PER SECTION | 43000.000 PICOFARADS SINGLE SECTION |
CASE INSULATION MATERIAL | PLASTIC |
CRITICALITY CODE JUSTIFICATION | FEAT |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1000 |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 40000.0 MEGOHMS |
INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
RELIABILITY INDICATOR | ESTABLISHED |
SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
SPECIAL FEATURES | DESIGN ANALYSIS |
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 SINGLE SECTION |
TERMINAL LENGTH | 1.500 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TERMINAL SURFACE TREATMENT | SOLDER |
TEST DATA DOCUMENT | 94756-441-1033 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
TOLERANCE RANGE PER SECTION | -1.00 TO 1.00 PERCENT SINGLE SECTION |