5910-00-112-7162 CAPACITOR,FIXED,PAPER DIELECTRIC Index 2520-00-112-7164 BALL,UNIVERSAL

National Stock Number:
5910-00-112-7163

Federal Supply Class:
5910

National Item Identification Number:
001127163

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
CP53B4EG254V00656AEROVOX CORP.
CP53B4EG254V156289SPRAGUE ELECTRIC CO WORLD HQS
CP53B4EG254V181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-25/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC2581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.875 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY STYLEW/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH1.750 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION0.250 MICROFARADS ALL SECTIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.375 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP20.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP26000.0 MEGOHMS
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED MOUNTING HOLES
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION1000.0 DC ALL SECTIONS
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORONE TERMINAL COMMON TO EACH SECTION
SECTION QUANTITY2
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-C-25 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 20.00 PERCENT 1ST SECTION AND -10.00 TO 20.00 PERCENT 2ND SECTION
UNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL


Click here to Register for Free 30-day Trial