5910-00-120-1686 CAPACITOR,FIXED,PLASTIC DIELECTR Index 5910-00-120-1688 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5910-00-120-1687

Federal Supply Class:
5910

National Item Identification Number:
001201687

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
120168718876U S ARMY AVIATION AND MISSILE COMMAND
3300-31764295380049DEPARTMENT OF THE AIR FORCE
39-1605690BARKER & WILLIAMSON
CP70E1EF405K181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-25/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC2581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
W604014655CORNELL-DUBILIER ELECTRONICS


Techincal Specification:
BODY HEIGHT3.875 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY WIDTH1.188 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION4.000 MICROFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.938 INCHES MINIMUM AND 1.187 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP20.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP2000.0 MEGOHM-MICROFARADS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION600.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL HEIGHT FROM BODY1.375 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 THREADED STUD
TEST DATA DOCUMENT81349-MIL-C-25 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION