5910-00-027-0165 CAPACITOR,FIXED,ELECTROLYTIC Index 5950-00-027-0168 REACTOR

National Stock Number:
5915-00-027-0167

Federal Supply Class:
5915

National Item Identification Number:
000270167

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1475903-117981SCI SYSTEMS INC
1475903-191417L3HARRIS TECHNOLOGIES, INC.
28-123406978VERNITRON CORP AIE MAGNETICS DIV


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION150.0 HERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTION1.00 HERTZ BLANK AND
300.00 HERTZ BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD2.5 KILOHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT7.5 KILOHMS BLANK
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
2 TAB, SOLDER LUG GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT0.640 INCHES NOMINAL
BODY LENGTH3.500 INCHES MAXIMUM
BODY HEIGHT0.500 INCHES MAXIMUM
BODY WIDTH1.250 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND
300.00 HERTZ BLANK AND
5.001 KILOHERTZ BLANK AND
50.00 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND
20.0 MINIMUM BLANK 1ST FUNCTION
OPERATING TEMP RANGE-54.0 TO 105.0 DEG CELSIUS
BODY MATERIALMETAL


Click here to Register for Free 30-day Trial