5950-00-032-6369 TRANSFORMER,POWER AUTOTRANSFORME Index 5910-00-032-6371 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5915-00-032-6370

Federal Supply Class:
5915

National Item Identification Number:
000326370

Description:
FILTER,HIGH PASS

Detail:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES ABOVE A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
205-075-696-158257ROCKWELL INTL CORP COLLINS GENERAL AVIATION COSTA MESA OPNS
205-075-696-197499BELL TEXTRON INC
HPF40-1558257ROCKWELL INTL CORP COLLINS GENERAL AVIATION COSTA MESA OPNS


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION15.0 WATTS BLANK 1ST FUNCTION
BODY HEIGHT1.000 INCHES MAXIMUM
BODY LENGTH3.900 INCHES MAXIMUM
BODY WIDTH2.400 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS80.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.375 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION225.00 MEGAHERTZ BLANK AND 400.00 MEGAHERTZ BLANK 1ST FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONM39012-17-0005
INPUT TERMINAL MANUFACTURER CODE81349
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK 1ST FUNCTION
OUTPUT TERMINAL IDENTIFICATIONM39012-17-0005
OUTPUT TERMINAL MANUFACTURER CODE81349
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE 1ST FUNCTION
OPERATING TEMP RANGE-25.0 TO 160.0 FAHRENHEIT
REFERENCE FREQUENCY PER FUNCTION312.5 MEGAHERTZ BLANK 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND 115.00 MEGAHERTZ BLANK AND 225.00 MEGAHERTZ BLANK AND 400.00 MEGAHERTZ BLANK 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION225.00 MEGAHERTZ BLANK AND 400.00 MEGAHERTZ BLANK 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.75 BLANK 1ST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT0.500 POUNDS NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.193 INCHES MINIMUM AND 0.198 INCHES MAXIMUM


Click here to Register for Free 30-day Trial