BODY LENGTH | 7.620 INCHES NOMINAL |
BODY MATERIAL | METAL |
BODY WIDTH | 6.620 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.500 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.250 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG INPUT 1ST FUNCTION |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
OVERALL HEIGHT | 3.940 INCHES NOMINAL |
OVERALL LENGTH | 8.250 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 5TH RADIO INTERFERENCE 5TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 6TH RADIO INTERFERENCE 6TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING TEMP RANGE | -65.0 TO 160.0 FAHRENHEIT |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNTHREADED MOUNTING HOLE DIAMETER | 0.235 INCHES NOMINAL |
VIBRATION RESISTANCE RANGE IN HERTZ | +5.0 TO 500.0 |