5915-00-057-3349 FILTER,RADIO FREQUENCY INTERFERE Index 5360-00-057-3351 SPRING,HELICAL,COMPRESSION

National Stock Number:
5915-00-057-3350

Federal Supply Class:
5915

National Item Identification Number:
000573350

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
227184810001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
238485456232LOCKHEED MARTIN CORPORATION
3B14213058SORA POWER INC.
A100459901MTK ELECTRONICS INC
FA-901913619EMS DEVELOPMENT CORPORATION
FA-901981831FILTRON CO INC DIV OF RFI CORP
NFR110-1593790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
BODY LENGTH0.781 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.484 INCHES NOMINAL
BODY SURFACE TREATMENTTIN
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH1.375 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE800.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
NOMINAL THREAD SIZE0.250 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 BLANK
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial