5945-00-080-6382 RELAY ASSEMBLY Index 5945-00-080-6387 SOLENOID,ELECTRICAL

National Stock Number:
5915-00-080-6385

Federal Supply Class:
5915

National Item Identification Number:
000806385

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2320-35990073CMC ELECTRONICS INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT1.859 INCHES NOMINAL
BODY LENGTH1.531 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.312 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION3.05 MEGAHERTZ BLANK AND 3.55 MEGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK
LOAD IMPEDANCE PER FUNCTION600.0 OHMS BLANK
OVERALL HEIGHT2.312 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION3.43 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.80 GIGAHERTZ BLANK AND 3.05 GIGAHERTZ BLANK AND 3.55 GIGAHERTZ BLANK AND 3.75 GIGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
UNTHREADED MOUNTING HOLE DIAMETER0.125 INCHES NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0


Click here to Register for Free 30-day Trial