AVERAGE LIFE RATING IN HOURS | 250.0 |
BODY HEIGHT | 1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM |
BODY LENGTH | 2.440 INCHES MINIMUM AND 2.560 INCHES MAXIMUM |
BODY WIDTH | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.045 INCHES MINIMUM AND 2.075 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.165 INCHES MINIMUM AND 1.195 INCHES MAXIMUM |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT-OUTPUT/GROUND |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OVERALL HEIGHT | 2.130 INCHES MINIMUM AND 2.250 INCHES MAXIMUM |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 200.0 VOLTS AT SEA LEVEL |
MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING TEMP RANGE | -65.0 TO 85.0 FAHRENHEIT |
SPECIAL FEATURES | 1.470 IN. MIN,1.530 IN. MAX O/A WIDTH |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.177 INCHES MINIMUM AND 0.197 INCHES MAXIMUM |