5930-00-119-7329 SWITCH,ROTARY Index 1650-00-119-7334 SERVOVALVE,HYDRAULIC

National Stock Number:
5915-00-119-7331

Federal Supply Class:
5915

National Item Identification Number:
001197331

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
39010-564547HONEYWELL INTERNATIONAL, INC
RME-F-00990S2B1RME FILTERS INC


Techincal Specification:
BODY HEIGHT3.170 INCHES MINIMUM AND 3.180 INCHES MAXIMUM
BODY LENGTH3.460 INCHES MINIMUM AND 3.470 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.930 INCHES MINIMUM AND 2.970 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.860 INCHES MINIMUM AND 3.880 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.730 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMS3106E20-7P
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
OUTPUT TERMINAL IDENTIFICATIONMS3106E20-7P
OUTPUT TERMINAL MANUFACTURER CODE96906
OVERALL LENGTH53.215 INCHES MINIMUM AND 55.225 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE230.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE56.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION350.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING TEMP RANGE-65.0 TO 165.0 FAHRENHEIT
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
SPECIAL FEATURESSIX FILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT3.000 POUNDS NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.200 INCHES MINIMUM AND 0.220 INCHES MAXIMUM