5915-00-124-4713 FILTER,BAND PASS Index 5915-00-124-4715 FILTER,BAND PASS

National Stock Number:
5915-00-124-4714

Federal Supply Class:
5915

National Item Identification Number:
001244714

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
113000003931196STELLANT PST CORP.
SMA75320831196STELLANT PST CORP.
SMA75320880063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
AVERAGE LIFE RATING IN HOURS11000000.0
BODY LENGTH0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH7.380 INCHES MINIMUM AND 7.400 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.307 INCHES MINIMUM AND 1.317 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH4.181 INCHES MINIMUM AND 4.191 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FEATURES PROVIDEDMOUNTING BRACKET AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION7.23 GIGAHERTZ BLANK AND 7.57 GIGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE31196
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE31196
OVERALL HEIGHT1.255 INCHES MAXIMUM
OVERALL LENGTH1.670 INCHES MINIMUM AND 1.690 INCHES MAXIMUM
OVERALL WIDTH8.125 INCHES MINIMUM AND 8.157 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING TEMP RANGE+7.0 TO 37.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION7.4 GIGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIAL FEATURESCONSISTS OF SEVEN TUNING SCREWS
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION7.05 GIGAHERTZ BLANK AND 7.23 GIGAHERTZ BLANK AND 7.57 GIGAHERTZ BLANK AND 7.75 GIGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION7.23 GIGAHERTZ BLANK AND 7.57 GIGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.35 BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.227 INCHES MINIMUM AND 0.233 INCHES MAXIMUM


Click here to Register for Free 30-day Trial