ACTUATOR FUNCTION | RESET |
BODY LENGTH | 2.560 INCHES NOMINAL |
BODY STYLE | SINGLE POLE TYPE |
BODY WIDTH | 0.630 INCHES NOMINAL |
BUSHING LENGTH | 0.250 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.625 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 150.0 MILLIAMPERES DC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.562 INCHES NOMINAL |
NOMINAL THREAD SIZE | 0.375 INCHES |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
POLE QUANTITY | 1 |
RESET METHOD | MANUAL |
TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
THREAD QUANTITY PER INCH | 32 |
THREAD SERIES DESIGNATOR | UNEF |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.800 MINIMUM AT 200 PCT AND 0.170 MAXIMUM AT 400 PCT SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |