5998-00-066-6889 CIRCUIT CARD ASSEMBLY Index 5925-00-066-6891 CIRCUIT BREAKER

National Stock Number:
5925-00-066-6890

Federal Supply Class:
5925

National Item Identification Number:
000666890

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
ATB2203024446GENERAL ELECTRIC COMPANY
ATB2203060969GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL


Techincal Specification:
POLE QUANTITY2
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE30.0 AMPERES AC AND
30.0 AMPERES DC ALL LOCATIONS
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
TERMINAL TYPE AND QUANTITY4 SCREW
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC AND
250.0 DC ALL LOCATIONS
TRIP RELEASE CHARACTERISTICINSTANTANEOUS AND
TIME DELAY ALL LOCATIONS
RESET METHODMANUAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
CASE MATERIALPLASTIC
TRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC AND
5000.0 DC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT75.000 MINIMUM AT 150 PCT AND
360.000 MAXIMUM AT 150 PCT AND
20.000 MINIMUM AT 200 PCT AND
63.000 MAXIMUM AT 200 PCT AND
8.000 MINIMUM AT 300 PCT AND
15.000 MAXIMUM AT 300 PCT AND
4.000 MINIMUM AT 400 PCT AND
8.000 MAXIMUM AT 400 PCT AND
2.500 MINIMUM AT 500 PCT AND
4.500 MAXIMUM AT 500 PCT AND
0.030 MINIMUM AT 1100 PCT AND
1.000 MAXIMUM AT 1100 PCT AND
0.010 MINIMUM AT 2000 PCT AND
0.020 MAXIMUM AT 2000 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT117.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
OVERALL LENGTH9.380 INCHES NOMINAL
OVERALL HEIGHT2.750 INCHES NOMINAL
OVERALL WIDTH4.690 INCHES NOMINAL
NOMINAL THREAD SIZE0.281 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTIONTRIP W/SEPARATE RESET
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
ARC QUENCHING METHODDEION
SPECIAL FEATURESMTG HOLES 0N 7.250 IN. BY 1.375 IN. MTG CENTERS