5925-00-109-1760 CIRCUIT BREAKER Index 5925-00-109-1765 CIRCUIT BREAKER

National Stock Number:
5925-00-109-1762

Federal Supply Class:
5925

National Item Identification Number:
001091762

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
43A8305-10580049DEPARTMENT OF THE AIR FORCE
612357-1098897LOCKHEED MARTIN CORP
PLM10582647SENSATA TECHNOLOGIES, INC.
VS2-425465-10514170HUGHES MISSILE SYSTEMS CO SAN DIEGO
VS2-425465-10581755LOCKHEED MARTIN CORPORATION


Techincal Specification:
CASE MATERIALPLASTIC
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY2 PUSH BUTTON
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS30.0 AC AND 30.0 DC SINGLE LOCATION
OVERALL HEIGHT1.828 INCHES NOMINAL
OVERALL LENGTH3.156 INCHES NOMINAL
OVERALL WIDTH1.875 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE105.0 AMPERES AC AND 105.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2100.0 AC AND 2100.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
POLE QUANTITY1
RESET METHODMANUAL
TERMINAL TYPE AND QUANTITY2 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT3600.000 NOMINAL AT 125 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL