CONTACT ADJUSTMENT RANGE | +33.00 TO 35.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 250.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CONTACT STIMULUS RATING | 2.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.219 INCHES NOMINAL |
OVERALL DIAMETER | 1.875 INCHES NOMINAL |
OVERALL LENGTH | 3.250 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | FLANGE |
NOMINAL THREAD SIZE | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
PRESSURE SWITCH TYPE | GAGE |
STYLE DESIGNATOR | CYLINDRICAL |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
THREAD CLASS | 3B SINGLE PRESSURE CONNECTION |
THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |