BULB DIAMETER | 0.125 INCHES NOMINAL |
BULB LENGTH | 2.500 INCHES NOMINAL |
CAPILLARY TUBE LENGTH | 144.000 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +85.00 TO 190.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 3.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 7.4 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CONTACT STIMULUS RATING | 4.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL THIRD VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SECOND VOLTAGE |
OVERALL HEIGHT | 4.938 INCHES NOMINAL |
OVERALL LENGTH | 15.875 INCHES NOMINAL |
OVERALL WIDTH | 4.875 INCHES NOMINAL |
MOUNTING METHOD | BRACKET |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
TERMINAL TYPE | TAB W/SCREW |