BODY LENGTH | 1.000 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 0.50 ACTUATION POINT NOMINAL INCHES OF WATER AND 0.40 DEACTUATION POINT NOMINAL INCHES OF WATER AND 0.10 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
CRITICALITY CODE JUSTIFICATION | FEAT |
INSIDE DIAMETER | 0.125 INCHES NOMINAL ALL CONNECTIONS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
OUTSIDE DIAMETER | 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM ALL CONNECTIONS |
OVERALL HEIGHT | 0.375 INCHES NOMINAL |
OVERALL LENGTH | 1.750 INCHES NOMINAL |
OVERALL WIDTH | 1.312 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | LIQUID |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
MOUNTING METHOD | BASE AND UNTHREADED HOLE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
OPERATING TEMP RATING | -40.0 FAHRENHEIT MINIMUM AND 150.0 FAHRENHEIT MAXIMUM |
PRESSURE CONNECTOR TYPE | BARBED, UNTHREADED EXTERNAL ALL CONNECTIONS |
PRESSURE SWITCH TYPE | GAGE |
SENSING ELEMENT BURST PRESSURE | 8.00 POUNDS PER SQUARE INCH GAGE |
SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
STYLE DESIGNATOR | RECTANGULAR |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.094 INCHES NOMINAL |