5935-00-062-1214 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5950-00-062-1216 REACTOR

National Stock Number:
5945-00-062-1215

Federal Supply Class:
5945

National Item Identification Number:
000621215

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
3346-9901399699DRI RELAYS INC.
9330-402796906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24149-A196906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.125 INCHES NOMINAL FIRST MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.125 INCHES NOMINAL SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.000 INCHES NOMINAL FIRST MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.000 INCHES NOMINAL SECOND MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE10.562 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FEATURES PROVIDEDCOIL VOLTAGE SUPPRESSION
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE6.0 AMPERES AC AND 6.0 AMPERES DC MOTOR LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT2.600 INCHES MAXIMUM
OVERALL LENGTH2.500 INCHES MAXIMUM
OVERALL WIDTH1.625 INCHES MAXIMUM
MOUNTING FACILITY PATTERNRECTANGULAR FIRST MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SECOND MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE FIRST MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE SECOND MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA96906-MS24149 GOVERNMENT STANDARD
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 SCREW ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY0.05 SECONDS MAXIMUM FIXED RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.173 INCHES NOMINAL FIRST MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER0.173 INCHES NOMINAL SECOND MOUNTING FACILITY