DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.068 INCHES MINIMUM AND 1.088 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CUBIC MEASURE | 0.698 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES AC AND 100.0 MILLIAMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 1.0 AC AND 1.0 DC |
OVERALL HEIGHT | 1.280 INCHES NOMINAL |
OVERALL LENGTH | 1.280 INCHES MINIMUM AND 1.330 INCHES MAXIMUM |
OVERALL WIDTH | 0.380 INCHES MINIMUM AND 0.410 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 40.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 10.0 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
UNTHREADED MOUNTING HOLE DIAMETER | 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY |