4820-00-062-8275 RETAINER,HELICAL COMPRESSION SPRING Index 5955-00-062-8286 CRYSTAL UNIT,QUARTZ

National Stock Number:
5945-00-062-8279

Federal Supply Class:
5945

National Item Identification Number:
000628279

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
4170600-2605869RAYTHEON COMPANY
6042H14881640SAFRAN POWER USA, LLC
6042H5027192DRS NAVAL POWER SYSTEMS INC
6042H5081640SAFRAN POWER USA, LLC
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24376-A296906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC AND 5.0 AMPERES DC INDUCTIVE LOAD
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE750.0 MILLIAMPERES AC AND 750.0 MILLIAMPERES DC LAMP LOAD
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE39.131 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES AC AND 50.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES AC AND 50.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES AC AND 50.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT4.485 INCHES NOMINAL
OVERALL LENGTH3.700 INCHES MAXIMUM
OVERALL WIDTH3.305 INCHES MAXIMUM
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
NONPILE-UP MAIN CONTACT ARRANGEMENT3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA96906-MS24376 GOVERNMENT STANDARD
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY12 THREADED STUD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.03 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY0.065 SECONDS MAXIMUM FIXED RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY