DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.870 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD |
OVERALL HEIGHT | 2.906 INCHES MAXIMUM |
OVERALL LENGTH | 1.880 INCHES MINIMUM AND 1.920 INCHES MAXIMUM |
OVERALL WIDTH | 1.460 INCHES MINIMUM AND 1.500 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 10 WIRE HOOK ALL FUNCTIONS |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TIME DELAY | 1.50 SECONDS NOMINAL FIXED OPERATE TIME |