Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
1256-503972CURTISS-WRIGHT CONTROLS ELECTRONIC SYSTEMS, INC.
1256-5-0003972CURTISS-WRIGHT CONTROLS ELECTRONIC SYSTEMS, INC.
613737-598897LOCKHEED MARTIN CORP


Techincal Specification:
DUTY TYPECONTINUOUS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.687 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
ENVIRONMENTAL PROTECTIONHERMETIC
FREQUENCY IN HERTZ320.0 NOMINAL
FSC APPLICATION DATARELAY ARMATURE,EXCEPT ENGINE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT1.500 INCHES NOMINAL
OVERALL LENGTH2.750 INCHES NOMINAL
OVERALL WIDTH2.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
WINDING QUANTITY2
TERMINAL TYPE AND QUANTITY7 PIN ALL FUNCTIONS
TIME DELAY1.00 SECONDS NOMINAL FIXED RELEASE TIME
TIME DELAY2.00 SECONDS NOMINAL FIXED OPERATE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.179 INCHES NOMINAL SINGLE MOUNTING FACILITY