DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CUBIC MEASURE | 1.544 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 8.0 DC |
OVERALL DIAMETER | 1.060 INCHES NOMINAL |
OVERALL LENGTH | 1.750 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.812 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIFICATION/STANDARD DATA | 96214-531710 MANUFACTURERS SPECIFICATION CONTROL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 250.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 TURRET CONTACTS |
TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG ENERGIZING ELEMENT |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UN SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
TIME DELAY | 0.018 SECONDS MAXIMUM FIXED OPERATE TIME |