DUTY TYPE | CONTINUOUSCONTINUOUS |
ARC QUENCHING METHOD | AIRAIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.805 INCHES NOMINAL SINGLE MOUNTING FACILITY0.805 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.225 INCHES NOMINAL SINGLE MOUNTING FACILITY0.225 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 11 |
CUBIC MEASURE | 0.992 CUBIC INCHES0.992 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETICHERMETIC |
FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES DC INDUCTIVE LOAD750.0 MILLIAMPERES DC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 115.0 AC AND 28.0 DC28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD100.0 MILLIAMPERES DC LAMP LOAD |
OVERALL HEIGHT | 0.817 INCHES MAXIMUM0.817 INCHES MAXIMUM |
OVERALL LENGTH | 1.491 INCHES MAXIMUM1.491 INCHES MAXIMUM |
OVERALL WIDTH | 0.815 INCHES MAXIMUM0.815 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITYDIAGONAL SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 6.0 MILLIAMPERES DC SINGLE WINDING6.0 MILLIAMPERES DC SINGLE WINDING |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY0.112 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERALGENERAL |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/13 GOVERNMENT SPECIFICATION81349-MIL-R-5757/13 GOVERNMENT SPECIFICATION |
WINDING DC RESISTANCE RATING | 4.5 KILOHMS MINIMUM AND 4.5 KILOHMS MINIMUM AND 5.5 KILOHMS MAXIMUM SINGLE WINDING5.5 KILOHMS MAXIMUM SINGLE WINDING |
WINDING QUANTITY | 11 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS8 WIRE HOOK ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY2A SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITYRIGHT-HAND SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY40 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITYUNC SINGLE MOUNTING FACILITY |
TIME DELAY | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME0.015 SECONDS MAXIMUM FIXED OPERATE TIME |