| DUTY TYPE | INTERMITTENT |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.191 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FREQUENCY IN HERTZ | 400.0 NOMINAL |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
| PROPRIETARY CHARACTERISTICS | PACS |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 1.430 INCHES NOMINAL |
| OVERALL LENGTH | 2.180 INCHES NOMINAL |
| OVERALL WIDTH | 1.620 INCHES NOMINAL |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |