| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND |
| 24.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC AND |
| 5.0 AMPERES AC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 100.0 VOLTS AC 25 DEG CELSIUS AND |
| 240.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 50.0 MINIMUM AND |
| 60.0 MAXIMUM |
| TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |
| TIME DELAY | 0.05 SECONDS MINIMUM AND |
| 180.00 HOURS MAXIMUM ADJUSTABLE OPERATE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
| OVERALL LENGTH | 2.812 INCHES NOMINAL |
| OVERALL WIDTH | 1.404 INCHES NOMINAL |
| OVERALL HEIGHT | 1.560 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | CIRUCLAR SINGLE MOUNTING FACILITY |