5950-00-040-9142 COIL,RADIO FREQUENCY Index 4710-00-040-9145 TUBE ASSEMBLY,METAL

National Stock Number:
5950-00-040-9144

Federal Supply Class:
5950

National Item Identification Number:
000409144

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
68A13F25030003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY HEIGHT1.375 INCHES NOMINAL
BODY LENGTH1.125 INCHES NOMINAL
BODY WIDTH1.341 INCHES NOMINAL
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT2000.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT279.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE11.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE180.40 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE7.40 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING3.5 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING3.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING31.7 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING2.2 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING20.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY10 WIRE LEAD