A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
160168-124930L3HARRIS TECHNOLOGIES, INC


Techincal Specification:
BODY LENGTH4.810 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH5.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT9.500 INCHES MAXIMUM
OVERALL WIDTH5.875 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.249 INCHES MINIMUM AND 0.255 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT25.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE21.20 AC VOLTS MINIMUM AND 42.40 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL AND GROUND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY7 STANDOFF, THREADED STUD