2910-00-049-3797 STRAINER,SEDIMENT Index 5120-00-049-3813 WRENCH,SPANNER

National Stock Number:
5950-00-049-3804

Federal Supply Class:
5950

National Item Identification Number:
000493804

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
637-002-92475138SHERJOR INC
81-4761744THOMAS R MILLER CO INC
86036261744THOMAS R MILLER CO INC
9000S6504 73993-1132537JOY GLOBAL UNDERGROUND MINING LLC
9000S6504 73993-1180064NAVAL SHIP SYSTEMS COMMAND
9000S6504-73993REVAPC1180064NAVAL SHIP SYSTEMS COMMAND


Techincal Specification:
BODY HEIGHT2.688 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY WIDTH2.188 INCHES NOMINAL
CRITICALITY CODE JUSTIFICATIONFEAT
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.406 INCHES NOMINAL AND 1.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEPARTIALLY INCLOSED, DOUBLE SHELL
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.164 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
WINDING OPERATING CURRENT1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE6.85 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING15.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY2 BINDING POST AND 2 WIRE LEAD


Click here to Register for Free 30-day Trial