5920-00-059-1106 FUSE,CARTRIDGE Index 5935-00-059-1109 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5950-00-059-1107

Federal Supply Class:
5950

National Item Identification Number:
000591107

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
180060680495ANDERSON AIRMOTIVE INC
180060697520BASLER ELECTRIC CO
1800606REVB03956NORTHROP GRUMMAN SYSTEMS CORPORATION
1800606REVB56232LOCKHEED MARTIN CORPORATION
557413483PRECISION ELECTRONICS, INC


Techincal Specification:
BODY LENGTH1.000 INCHES NOMINAL
BODY OUTSIDE DIAMETER1.500 INCHES NOMINAL
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP85.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING HOLE DIAMETER0.193 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE2.225 AC VOLTS NOMINAL AND 1.636 AC VOLTS NOMINAL AND 8.899 AC VOLTS NOMINAL AND 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY8 TURRET