5950-00-062-1499 REACTOR-TRANSFORMER Index 5950-00-062-1511 REACTOR-TRANSFORMER

National Stock Number:
5950-00-062-1509

Federal Supply Class:
5950

National Item Identification Number:
000621509

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
30046620B6S1INTERNATIONAL BUSINESS MACHINES CORP PARTS ORDER CENTER DEPT E - 54
300466211327INTERNATIONAL BUSINESS MACHINES CORP
300466230874INTERNATIONAL BUSINESS MACHINES CORPORATION
FM74891709FUGLE-MILLER LABORATORIES


Techincal Specification:
BODY LENGTH1.052 INCHES MINIMUM AND 1.072 INCHES MAXIMUM
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING6.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
OVERALL DIAMETER0.735 INCHES MINIMUM AND 0.775 INCHES MAXIMUM
MOUNTING METHODTERMINAL SINGLE GROUP
QUALITY FACTOR55 MINIMUM AND 80 MAXIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT100.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 WIRE LEAD