5999-00-119-8992 CONTACT,ELECTRICAL Index 5955-00-119-8994 CRYSTAL UNIT,QUARTZ

National Stock Number:
5955-00-119-8993

Federal Supply Class:
5955

National Item Identification Number:
001198993

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
CR25/U320K000081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-3098/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-3098/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING1.6 MILLIWATTS MINIMUM AND 2.4 MILLIWATTS MAXIMUM
BODY LENGTH0.775 INCHES MAXIMUM
BODY WIDTH0.725 INCHES MAXIMUM
BODY THICKNESS0.317 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.478 INCHES MINIMUM AND 0.494 INCHES MAXIMUM
CIRCUIT RESONANCESERIES RESONANCE
EQUIVALENT RESISTANCE VALUE IN OHMS4000.0 MAXIMUM
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.010 TO 0.010
OVERALL LENGTH0.998 INCHES MINIMUM AND 1.023 INCHES MAXIMUM
OVERALL THICKNESS0.352 INCHES MAXIMUM
OVERALL WIDTH0.757 INCHES MAXIMUM
MODE OF OSCILLATIONFUNDAMENTAL
OPERATING TEMP RANGE-40.0 TO 85.0 CELSIUS
SPECIFICATION/STANDARD DATA81349-MIL-C-3098/7 GOVERNMENT SPECIFICATION
SPECIFIED FREQUENCY320.000 KILOHERTZ
STYLE DESIGNATOROVAL BODY, PIN TERMINALS
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
TERMINAL DIAMETER0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MIL-C-3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial