ELECTRODE INTERNALLY-ELECTRICALLY CONNECTED TO CASE | DRAINDRAIN |
CURRENT RATING PER CHARACTERISTIC | 10.00 MILLIAMPERES MAXIMUM FORWARD GATE CURRENT10.00 MILLIAMPERES MAXIMUM FORWARD GATE CURRENT |
INTERNAL CONFIGURATION | FIELD EFFECTFIELD EFFECT |
OVERALL DIAMETER | 0.209 INCHES MINIMUM AND 0.209 INCHES MINIMUM AND 0.230 INCHES MAXIMUM0.230 INCHES MAXIMUM |
OVERALL LENGTH | 0.170 INCHES MINIMUM AND 0.170 INCHES MINIMUM AND 0.210 INCHES MAXIMUM0.210 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 200.0 CELSIUS AMBIENT AIR200.0 CELSIUS AMBIENT AIR |
MOUNTING METHOD | TERMINALTERMINAL |
POWER RATING PER CHARACTERISTIC | 300.0 MILLIWATTS MAXIMUM TOTAL POWER DISSIPATION300.0 MILLIWATTS MAXIMUM TOTAL POWER DISSIPATION |
SEMICONDUCTOR MATERIAL | SILICONSILICON |
SPECIFICATION/STANDARD DATA | 81349-MIL-S-19500/375 GOVERNMENT SPECIFICATION81349-MIL-S-19500/375 GOVERNMENT SPECIFICATION |
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 30.0 MAXIMUM DRAIN TO GATE VOLTAGE AND 30.0 MAXIMUM DRAIN TO GATE VOLTAGE AND 30.0 MAXIMUM DRAIN TO SOURCE VOLTAGE AND 30.0 MAXIMUM DRAIN TO SOURCE VOLTAGE AND 30.0 MAXIMUM REVERSE GATE TO SOURCE VOLTAGE30.0 MAXIMUM REVERSE GATE TO SOURCE VOLTAGE |
TERMINAL CIRCLE DIAMETER | 0.100 INCHES NOMINAL0.100 INCHES NOMINAL |
TERMINAL LENGTH | 0.500 INCHES MINIMUM AND 0.500 INCHES MINIMUM AND 0.750 INCHES MAXIMUM0.750 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 4 UNINSULATED WIRE LEAD4 UNINSULATED WIRE LEAD |
TEST DATA DOCUMENT | 81349-MIL-S-19500 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).81349-MIL-S-19500 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |