5985-00-070-8132 WAVEGUIDE ASSEMBLY Index 1285-00-070-8136 WINDOW

National Stock Number:
5985-00-070-8133

Federal Supply Class:
5985

National Item Identification Number:
000708133

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
100272756232LOCKHEED MARTIN CORPORATION
232288010001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
23228805Z167ASTRO MICROWAVE INC


Techincal Specification:
BEND ANGLE IN DEG90.0 ALL BENDS H-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATERIALALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
PRECIOUS MATERIAL AND LOCATIONINTERNAL SURFACES GOLD AND INTERNAL SURFACES SILVER
PRECIOUS MATERIALGOLD AND SILVER
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
WAVEGUIDE LONGER OFFSET DISTANCE5.719 INCHES MINIMUM AND 5.781 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE0.500 INCHES NOMINAL
STYLE DESIGNATORBEND TYPE
SURFACE TREATMENTCHROMATE AND CHROMATE ZINC AND ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
SURFACE TREATMENTSILVER AND GOLD SINGLE TUBING SEGMENT INSIDE SURFACES
THREAD CLASS32 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNC FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT


Click here to Register for Free 30-day Trial