BEND ANGLE IN DEG | 123.0 SINGLE BEND E-PLANE |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES SECOND CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.167 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES SECOND CONNECTION FACILITY |
FLANGE INSIDE DIAMETER | 1.013 INCHES NOMINAL FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.500 INCHES MINIMUM AND 0.506 INCHES MAXIMUM SECOND FLANGE |
FLANGE DEPTH | 0.156 INCHES NOMINAL SECOND FLANGE |
FLANGE DEPTH | 0.438 INCHES NOMINAL FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 1.000 INCHES MINIMUM AND 1.006 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL SECOND FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
FLANGE STYLE | COVER TYPE SECOND FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
NOMINAL THREAD SIZE | 0.164 INCHES ALL FLANGES FIRST CONNECTION FACILITY |
PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES GOLD AND INTERNAL SURFACES SILVER |
PRECIOUS MATERIAL | GOLD AND SILVER |
SPECIAL FEATURES | TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
WAVEGUIDE INSIDE HEIGHT | 0.499 INCHES MINIMUM AND 0.502 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.899 INCHES MINIMUM AND 0.902 INCHES MAXIMUM |
WAVEGUIDE OFFSET DISTANCE | 7.603 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.899 INCHES MINIMUM AND 0.902 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.999 INCHES MINIMUM AND 1.002 INCHES MAXIMUM |
WAVEGUIDE LONGER OFFSET DISTANCE | 11.774 INCHES NOMINAL |
STYLE DESIGNATOR | BEND TYPE |
SURFACE TREATMENT | CHROMATE ZINC AND ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | GOLD AND SILVER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES |
THREAD CLASS | 2B ALL FLANGES FIRST CONNECTION FACILITY |
THREAD DIRECTION | RIGHT-HAND ALL FLANGES FIRST CONNECTION FACILITY |
THREAD SERIES DESIGNATOR | UNC ALL FLANGES FIRST CONNECTION FACILITY |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |