BEND ANGLE IN DEG | 90.0 ALL BENDS E-PLANE |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL FIRST FLANGE SINGLE CONNECTION FACILITY |
FLANGE INSIDE DIAMETER | 1.625 INCHES NOMINAL ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.497 INCHES NOMINAL FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.628 INCHES NOMINAL SECOND FLANGE |
FLANGE DEPTH | 0.438 INCHES NOMINAL SECOND FLANGE |
FLANGE DEPTH | 0.625 INCHES NOMINAL FIRST FLANGE |
FLANGE INSIDE WIDTH | 1.122 INCHES NOMINAL FIRST FLANGE |
FLANGE INSIDE WIDTH | 1.253 INCHES NOMINAL SECOND FLANGE |
FLANGE OUTSIDE HEIGHT | 1.875 INCHES NOMINAL FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.875 INCHES NOMINAL SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.875 INCHES NOMINAL FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.875 INCHES NOMINAL SECOND FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
FLANGE STYLE | COVER TYPE SECOND FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | MULTIAPPLICATION |
MATERIAL | ALUMINUM ALL TUBING SEGMENT |
NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE SINGLE CONNECTION FACILITY |
WAVEGUIDE OUTSIDE HEIGHT | 0.625 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 1.250 INCHES NOMINAL |
WAVEGUIDE CENTER TO CENTER DISTANCE | 3.550 INCHES NOMINAL |
WAVEGUIDE HEIGHT | 3.758 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.497 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 1.122 INCHES NOMINAL |
STYLE DESIGNATOR | DOUBLE BEND TYPE |
SURFACE TREATMENT | ANODIZE ALL TUBING SEGMENT INSIDE SURFACES |
SURFACE TREATMENT | ANODIZE AND ENAMEL ALL TUBING SEGMENT OUTSIDE SURFACES |
THREAD CLASS | 2B SECOND FLANGE SINGLE CONNECTION FACILITY |
THREAD DIRECTION | RIGHT-HAND SECOND FLANGE SINGLE CONNECTION FACILITY |
THREAD SERIES DESIGNATOR | UNC SECOND FLANGE SINGLE CONNECTION FACILITY |
THREAD QUANTITY PER INCH | 32 SECOND FLANGE SINGLE CONNECTION FACILITY |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |